Single and Multiple Stimulus Static Perimetry in Glaucoma; The Two Phases of Perimetry

The Two Phases of Perimetry

Nonfiction, Health & Well Being, Medical, Specialties, Ophthalmology
Cover of the book Single and Multiple Stimulus Static Perimetry in Glaucoma; The Two Phases of Perimetry by E.L. Greve, Springer Netherlands
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: E.L. Greve ISBN: 9789401177658
Publisher: Springer Netherlands Publication: December 6, 2012
Imprint: Springer Language: English
Author: E.L. Greve
ISBN: 9789401177658
Publisher: Springer Netherlands
Publication: December 6, 2012
Imprint: Springer
Language: English

does not vary more than 1 % over the whole surface. Stimulus: The luminance of the stimuli can be regulated by means of neutral density filters. These filters are neither entirely neutral nor completely uniform, but these variations are not significant for perimetry. The maximum luminance of the stimuli is standardized at 1000 asb (316 2 cd.m-). The standard GP for kinetic perimetry has 3 neutral density filters which reduce the luminance by 0.5, 1.0 and 1.5 log units respectively. The modification of the GP for static perimetry is supplied with an additional series of four neutral density filters, which allow luminance steps of 0.1, 0.2, 0.3 and 0.4 log units. The resulting luminance values, expressed in apostilb, are given in Table I. TABLE I Luminance values of the Goldmann perimeter 4 3 2 steps lux 1430 450 143 45 3,1 asb 1000 315 100 31,5 3,1 2 cd/m 315 100 31,5 10 3,1 ßL ±30 10 3 3,1 L log L asb 3 2,5 2 2 1,5 0,5 2 Background: 31,5 asb. = 10 cd/m • Coefficient of reflection 0,7. 1 2 (1 asb = -cd/m).

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

does not vary more than 1 % over the whole surface. Stimulus: The luminance of the stimuli can be regulated by means of neutral density filters. These filters are neither entirely neutral nor completely uniform, but these variations are not significant for perimetry. The maximum luminance of the stimuli is standardized at 1000 asb (316 2 cd.m-). The standard GP for kinetic perimetry has 3 neutral density filters which reduce the luminance by 0.5, 1.0 and 1.5 log units respectively. The modification of the GP for static perimetry is supplied with an additional series of four neutral density filters, which allow luminance steps of 0.1, 0.2, 0.3 and 0.4 log units. The resulting luminance values, expressed in apostilb, are given in Table I. TABLE I Luminance values of the Goldmann perimeter 4 3 2 steps lux 1430 450 143 45 3,1 asb 1000 315 100 31,5 3,1 2 cd/m 315 100 31,5 10 3,1 ßL ±30 10 3 3,1 L log L asb 3 2,5 2 2 1,5 0,5 2 Background: 31,5 asb. = 10 cd/m • Coefficient of reflection 0,7. 1 2 (1 asb = -cd/m).

More books from Springer Netherlands

Cover of the book Fate of Pesticides in the Atmosphere: Implications for Environmental Risk Assessment by E.L. Greve
Cover of the book The Exploration of Supramolecular Systems and Nanostructures by Photochemical Techniques by E.L. Greve
Cover of the book Regionalizing Oman by E.L. Greve
Cover of the book Introduction to Optimization Methods by E.L. Greve
Cover of the book The Meaning of Meaninglessness by E.L. Greve
Cover of the book Machines and Signs by E.L. Greve
Cover of the book Instrumental Rationality and Moral Philosophy by E.L. Greve
Cover of the book Imaging Radar for Resources Surveys by E.L. Greve
Cover of the book The Global Paleomagnetic Database by E.L. Greve
Cover of the book Sustainable Livelihood Approach by E.L. Greve
Cover of the book Intercellular Communication in Cancer by E.L. Greve
Cover of the book Henry E. Kyburg, Jr. & Isaac Levi by E.L. Greve
Cover of the book Insect Behavior by E.L. Greve
Cover of the book Water-Quality Hydrology by E.L. Greve
Cover of the book Advances in Food Protection by E.L. Greve
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy